CAS Board Mount Current Transducers

LEM CAS Board Mount Current Transducers are designed for accurate electronic measurement of DC, AC, and pulsed currents, ranging from 1.5A RMS to 75A RMS, with galvanic isolation between the primary and secondary circuits. These Fluxgate-based transducers operate on a single +5V supply, ensuring low offset and gain drift. With a measuring range extending up to three times the nominal primary current (Ipn), the transducers offer high precision and reliability for various applications. Additionally, the LEM CAS sensors are designed for PCB mounting, making them easy to integrate into electronic systems.

Resultados: 6
Seleccionar Imagen N.° de pieza Fabricante: Descripción Hoja de datos Disponibilidad Precio: (USD) Filtre los resultados en la tabla por precio unitario en función de su cantidad. Cantidad RoHS Modelo ECAD Régimen de corriente Tipo de sensor Tiempo de respuesta Exactitud Banda de frecuencias Voltaje de alimentación operativo Tipo de salida
LEM Sensores de corriente montados en placa Current Transducer CAS series. For the electronic measurement of current: DC, AC, pulsed..., with galvanic seperation between the primary and the secondary circuit. 286En existencias
200Se espera el 24/4/2026
Min.: 1
Mult.: 1

15 A Closed Loop 300 ps 0.8 % 300 kHz 5 V Digital, Analog
LEM Sensores de corriente montados en placa Current Transducer CAS series. For the electronic measurement of current: DC, AC, pulsed..., with galvanic seperation between the primary and the secondary circuit. 443En existencias
200Se espera el 24/3/2026
Min.: 1
Mult.: 1

25 A Closed Loop 300 ps 0.8 % 300 kHz 5 V Digital, Analog
LEM Sensores de corriente montados en placa Current Transducer CAS series. For the electronic measurement of current: DC, AC, pulsed..., with galvanic seperation between the primary and the secondary circuit. 165En existencias
Min.: 1
Mult.: 1

50 A Closed Loop 300 ps 0.8 % 300 kHz 5 V Digital, Analog
LEM Sensores de corriente montados en placa Current Transducer CAS series. For the electronic measurement of current: DC, AC, pulsed..., with galvanic seperation between the primary and the secondary circuit. 598En existencias
Min.: 1
Mult.: 1

6 A Closed Loop 300 ps 0.8 % 300 kHz 5 V Digital, Analog
LEM Sensores de corriente montados en placa Plazo de entrega no en existencias 14 Semanas
Min.: 200
Mult.: 200
15 A Closed Loop 300 ps 0.8 % 300 kHz 5 V Digital, Analog
LEM Sensores de corriente montados en placa Plazo de entrega no en existencias 14 Semanas
Min.: 200
Mult.: 200
25 A Closed Loop 300 ps 0.8 % 300 kHz 5 V Digital, Analog